无市政给水时高层建筑的室外消防给水设计初探
引用本文:费海新,王楠.无市政给水时高层建筑的室外消防给水设计初探[J].价值工程,2011,30(6):162-162.
作者姓名:费海新  王楠
作者单位:石家庄市公安消防支队,石家庄,050000
摘    要:本文结合《高层民用建筑防火规范》,介绍了在没有市政给水的情况下,高层建筑小区室外消防给水三种方案,结合其设置要求、安全性、工作原理分析了系统特点和局限性,并推荐最优方案。

关 键 词:无市政给水  高层建筑  室外消火栓给水系统  室外消火栓

Exploration on Outdoor Fire Water Supply Design in High Rise Building without Municipal Water Supply
Fei Haixin,Wang Nan.Exploration on Outdoor Fire Water Supply Design in High Rise Building without Municipal Water Supply[J].Value Engineering,2011,30(6):162-162.
Authors:Fei Haixin  Wang Nan
Institution:Fei Haixin,Wang Nan(Shijiazhuang Public Security Fire Brigade,Shijiazhuang 050000,China)
Abstract:In this paper,combined with fire Protection code of high rise civil buildings,three programs of fire water supply outdoor residential high-rise buildings are introduced in the case of no municipal water supply.With the set requirements,safety and working principle,the paper analyzes system characteristics and limitations and recommends the best solution.
Keywords:no municipal water supply  high-rise building  outdoor fire hydrant water supply system  outdoor fire hydrant  