首页 | 本学科首页   官方微博 | 高级检索  
     检索      

方钢管混凝土柱轴压比限值的研究
引用本文:黄秋英.方钢管混凝土柱轴压比限值的研究[J].价值工程,2010,29(10):107-108.
作者姓名:黄秋英
作者单位:江西省抚州市市政工程管理处,抚州,344000
摘    要:本文在方钢管混凝土柱压弯试验的基础上,探讨了轴压比影响柱延性的原因,并推导了试验轴压比与设计轴压比的换算关系公式。最后根据换算关系公式和试验数据,以层间弹塑性位移角作为延性控制指标,提出了方钢管混凝土框架柱的轴压比限值,以供设计参考。

关 键 词:钢管混凝土  轴压比  轴压比限值  延性

Study on Limited Values of Axial Compression Ratio of Concrete Filled Square Steel Tubular Columns
Huang Qiuying.Study on Limited Values of Axial Compression Ratio of Concrete Filled Square Steel Tubular Columns[J].Value Engineering,2010,29(10):107-108.
Authors:Huang Qiuying
Institution:Jiangxi Province/a>;Fuzhou Municipal Engineering Administration Department/a>;Fuzhou 344000/a>;China
Abstract:This paper based on experiment of concrete filled square steel tubular columns under combined constant axial load and cyclic lateral loads, the reasons of the effect of axial compression ratio on the ductility of composite column are discussed in this paper .The conversion relation between experimental axial compression ratio and design axial compression ratio is deduced .Finally, the limited values of axial compression ratio of concrete filled square steel tubular columns are brought forward on the basis o...
Keywords:concrete filled square steel tubular columns  axial compression ratio  limited values of axial compression ratio  ductility  
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号