排涝泵站电动机严重受潮问题的探讨
引用本文:覃志巩.排涝泵站电动机严重受潮问题的探讨[J].企业科技与发展,2010(9):66-67.
作者姓名:覃志巩
作者单位:柳州市防洪堤管理处,广西柳州545002
摘    要:文章根据某泵站实际运行管理情况,总结运行生产方面经验,分析泵站电动机严重受潮原因,并提出了处理意见,以加强设备保护,有效降低故障发生时设备的损坏率,保证设备长期安全运行。

关 键 词:排涝泵站  电动机  受潮处理

The Problem of the Damped Electric Motor at the Draining Water-logged Pump Station
Authors:QIN Zhi-gong
Institution:QIN Zhi-gong (Liuzhou Flood Dike Management Office,Liuzhou Guangxi 545002)
Abstract:Based on the operation and management of a pump station,the article summarizes the experiences about production operation,analyzes the reasons why the electric motor at pump station is seriously affected with damp,and sets forth the solutions,as parts of the efforts to improve the equipment protection,effectively reduce the damage caused the equipment's faults and ensure its long-term safety operation.
Keywords:water-logged pump station  electric motor  solutions for the damp