摘    要:由于机组启动时候对给水、凝结水的含铁量要求较高,只有其合格才允许进行机组启动操作的下一步操作,而目前常用的测定铁含量的方法耗时较多,在机组启动过程中很难适应机组启动要求。通过大量实验,对目前国标规定的实验方法进行了一些改进,可以快速测定含铁量,误差完全可以满足机组启动需求。

关 键 词:机组启动  含铁量  快速测定

Discussion on Iron Content Mensuration Amelioration in Machine Union Stratup Phase of Thermal Power Plant
Chen Rong. Discussion on Iron Content Mensuration Amelioration in Machine Union Stratup Phase of Thermal Power Plant[J]. , 2011, 0(8): 154-155
Authors:Chen Rong
Abstract:With the stant of the machine union,there is a requirement of iron content in waters.The machine union can't step further except the requirement was satisfied.But the popular mensuration costs much time,which is hard to reach the requirement.Based on a lot of experiments,make some amelioration of experimentations,to mensurate iron content in a short time,and the error satisfies the requirement of machine union stratup.