首页 | 本学科首页   官方微博 | 高级检索  
     检索      

600MW机组锅炉送风机节能改造效果
引用本文:丁连生.600MW机组锅炉送风机节能改造效果[J].电力技术经济,2011,23(4):38-41.
作者姓名:丁连生
作者单位:神华浙江国华浙能发电有限公司,浙江宁波,315612
摘    要:宁海电厂600MW机组锅炉送风机由于设计选型时裕量偏大,送风机长期在低效率区运行,浪费了大量的电能。在试验和分析的基础上,对送风机叶轮和电机进行了风机转子、轮毂和叶片等的改造。改造后送风机实际运行效率明显提高,送风机的厂用电率从改造前的0.135%下降到改造后的0.105%,经济效益明显,达到了节能改造的目的。

关 键 词:火力发电厂  锅炉送风机  节能改造

Efficiency Improvement of Forced Draft Fan in the 600 MW Boiler
DING Liansheng.Efficiency Improvement of Forced Draft Fan in the 600 MW Boiler[J].Electric Power Technologic Economics,2011,23(4):38-41.
Authors:DING Liansheng
Institution:DING Liansheng (Shenhua Zhejiang Guohua Zheneng Power Generation Co., Ltd, Ningbo 315612, China)
Abstract:With a redundant capacity allowance in its design, the forced draft fan for the 600 MW boiler in Ninghai Power Plant has operated at a low efficiency for a long time, therefore causing considerable waste of energy. Through tests and analysis, an improvement is made on the rotator, the wheel hub and the blades, and other parts of the forced draft fan. The improvement results in a notable increase of efficiency and remarkable economical benefits, with the auxiliary power consumption rate of the fan dropping from 0.135% to 0.105% following the renovation, thus realizing the proposed goal of energy saving.
Keywords:thermal power plant  forced draft fan  energy-saving improvement
本文献已被 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号