110kV电流互感器油色谱异常分析与处理
引用本文:龚辉. 110kV电流互感器油色谱异常分析与处理[J]. 价值工程, 2014, 0(25): 48-49
作者姓名:龚辉
作者单位:国网朔州供电公司,朔州036002
摘    要:针对朔州110kV增子坊变电站110kV玉增线194断路器A相CT油色谱异常情况,进行了故障原因和气体来源的分析,确定了故障类型,介绍了故障的处理情况及该相互感器的解体过程,对发现的问题进行了总结,为同行提供了经验。

关 键 词:电流互感器  色谱分析  故障分析  预防措施

Analysis and Treatment of Oil Chromatographic Abnormality for 110kV Current Transformer
GONG Hui. Analysis and Treatment of Oil Chromatographic Abnormality for 110kV Current Transformer[J]. Value Engineering, 2014, 0(25): 48-49
Authors:GONG Hui
Affiliation:GONG Hui( State Grid Shuozhou Power Company, Shuozhou 036002, China )
Abstract:For the oil chromatographic abnormality of Shuozhou 110 kV Zengzifang transformer substation 110 kV Yuzeng line 194 A CT,this paper analyzed the causes of fault and the gas source, determined the type of fault, described the handling of faults and the disintegration process of transformer, and summarized the problems discovered, to provide experience for peer.
Keywords:current transformer  chromatography analysis  fault analysis  preventive measures