引用本文:罗允忠.浅谈10kV线路氧化锌避雷器的创新安装[J].企业技术开发,2012(16):35-36,42.
作者姓名:罗允忠
作者单位:福建省电力有限公司宁德电业局
摘    要:避雷器的结构和材料特性决定了避雷效果及其安装环境。文章阐述了在线路避雷中选用氧化锌避雷器时,其与高压隔离开关及配合安装方式能够有效提高供电可靠性,减小运行维护难度。

关 键 词:避雷器  安装  线路

On the innovative installation of 10 kV line zinc oxide arresters
LUO Yun-zhong.On the innovative installation of 10 kV line zinc oxide arresters[J].Technological Development of Enterprise,2012(16):35-36,42.
Authors:LUO Yun-zhong
Institution:LUO Yun-zhong (Ningde Power Bureau of Fujian Electric Power Co.,Ltd.,Ningde,Fujian 352100,China)
Abstract:The structure and material properties of the arrester determine the effect of lightning protection and its installation environment.This paper explains that when the zinc oxide arresters is chosen in line lightning protection,the installation of matching up it,hv switch-disconnector and are-protection hardware can effectively improve the reliability of power supply and reduce the difficulty of operation maintenance.