首页 | 本学科首页   官方微博 | 高级检索  
     

断层破碎带与洞室间距对地下水封洞库洞室稳定性的影响研究
引用本文:刘鹏,赵青,陈轶磊,金伍. 断层破碎带与洞室间距对地下水封洞库洞室稳定性的影响研究[J]. 长江科学院院报, 2018, 35(8): 151-153. DOI: 10.11988/ckyyb.20180470
作者姓名:刘鹏  赵青  陈轶磊  金伍
作者单位:1.中国电建集团 中南勘测设计研究院有限公司,长沙 410014;2.长江科学院 武汉长江科创科技发展有限公司, 武汉 430010;3.四川中良建筑工程有限公司,成都 610094
摘    要:地下水封洞库通常在花岗岩等硬质岩体中开挖形成,其库区地质构造多发育有断裂构造、节理裂隙等不良地质结构。为了探究断层破碎带对地下水封洞库洞室稳定性的影响,依据湛江地下水封洞库库址区地质构造及地应力实测资料,基于FLAC3D有限差分软件,分析了断层破碎带距洞室不同距离时的围岩位移及模型断面典型位置的位移。结果表明:①断层破碎带位置对洞室近边墙围岩稳定性影响较大,对远边墙围岩稳定性影响较小;②当断层破碎带距离近边墙的距离超过1/2洞室跨度时,断层破碎带对洞室围岩稳定性影响可忽略。研究成果对于类似洞库工程选址及安全距离的选择具有良好的指导作用。

关 键 词:地下水封洞库洞室  断层破碎带  FLAC3D  围岩稳定性  数值模拟  
收稿时间:2018-05-08

Influence of the Distance Between Fault Fracture Zone and Cavern on the Stability of Underground Water-sealed Oil Storage Cavern
LIU Peng,ZHAO Qing,CHEN Yi-lei,JIN Wu. Influence of the Distance Between Fault Fracture Zone and Cavern on the Stability of Underground Water-sealed Oil Storage Cavern[J]. Journal of Yangtze River Scientific Research Institute, 2018, 35(8): 151-153. DOI: 10.11988/ckyyb.20180470
Authors:LIU Peng  ZHAO Qing  CHEN Yi-lei  JIN Wu
Affiliation:1.Power China Zhongnan Engineering Corporation Limited, Changsha 410014, China;2.Wuhan Changjiang Kechuang Technology Development Co., Ltd., Yangtze River Scientific Research Institute, Wuhan 430010, China;3.Sichuan Zhongliang Construction Engineering Co., Ltd., Chengdu 610094, China
Abstract:Underground water-sealed caverns are usually excavated in granite and other hard rock masses where defective geological structures such as faults and joints develop well. In an attempt to investigate into the influence of fault fracture zone on the stability of underground cavern, we examined the displacements of surrounding rock and typical sections in FLAC3D with varying distance between fault fracture zone and cavern. The conclusions are as follows: (1) The location of fault fracture zone has great influence on the stability of surrounding rock of adjacent side wall, but has little influence on the stability of surrounding rock of distant side wall; (2) When the distance between fault fracture zone and cavern exceeds half of the cavern span, the influence of fault fracture zone on the stability of surrounding rock can be neglected. The conclusions are of guiding importance for determining the safe distance and selecting the location of such caverns.
Keywords:underground water-sealed oil storage cavern  fault fracture zone  FLAC3D  surrounding rock stability  numerical simulation  
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《长江科学院院报》浏览原始摘要信息
点击此处可从《长江科学院院报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏