分相电流差动保护动作判据的研究 |
| |
引用本文: | 邬克伟,王毅.分相电流差动保护动作判据的研究[J].企业科技与发展,2008(12):148-151. |
| |
作者姓名: | 邬克伟 王毅 |
| |
作者单位: | 大唐桂冠合山发电有限公司,广西合山546501 |
| |
摘 要: | 文章通过利用MATLAB软件中的Simulink工具箱对电力系统的短路故障进行模拟,并对分相电流差动纵联保护动作判据进行动作行为的分析。仿真的结果表明,分相电流差动纵联保护对各种短路故障的判断具有绝对的选择性和较高的灵敏性。
|
关 键 词: | 电力系统 分相电流差动保护 仿真分析 |
On the Criterion of Single-Phase Current Differential Protection |
| |
Authors: | WU Ke-wei WANG Yi |
| |
Institution: | ( Dathang Guiguan Heshan Power Generation Co., Ltd., Heshan Guangxi 546501 ) |
| |
Abstract: | By using the Simulink toolbox of the MATLAB, the article simulates on the short-circuit fault of the electric power system and analyzes the single-phase current pilot differential relay operating characteristics. The simulation results show that the segregated current pilot differential protection is absolutely selective and highly sensitive in judging the short-circuit fault. |
| |
Keywords: | electric power system segregated current differential protection emulation analysis |
本文献已被 维普 等数据库收录! |