摘    要:阐述了氨进入熔盐系统对三聚氰胺装置的危害,并通过实例分析将氨过热器加热方式由原来的套管式换热器改为电加热器的必要性.

关 键 词:氨过热器  电加热  必要性  三胺  装置  过热器  加热方式  superheater  ammonia  means  heating  necessity  analysis  电加热器  套管式换热器  实例分析  三聚氰胺  系统  熔盐  阐述
文章编号:1009-4725(2007)8-0028-02
修稿时间:2007-06-04

An elementary analysis on the necessity of exchanging the heating means of ammonia superheater
Liu Yanfei.An elementary analysis on the necessity of exchanging the heating means of ammonia superheater[J].Chemical Technology Market,2007,30(8):28-29,44.
Authors:Liu Yanfei
Institution:Zhongyuan Dahua Group Co. , Ltd. , Puyang city,Henan Province 457004, China
Abstract:Elaborate on the peril of the melamine plant when ammonia entering into the melting salt system, and analyzed the necessity of exchanging the double pipes heat exchanger with electrical heater for the ammonia superheater.