电除尘内部结焦原因分析及预防措施探讨
引用本文:胡新立.电除尘内部结焦原因分析及预防措施探讨[J].价值工程,2014(10):49-50.
作者姓名:胡新立
作者单位:大唐户县热电厂,户县710302
摘    要:本文介绍了某发电厂2×600MW机组电除尘内部结焦情况,并就三、四、五电场除尘内部结焦原因进行了分析,提出了预防电除尘内部结焦的技术措施,解决了输灰管线不畅和电除尘内部结焦严重被迫停炉的问题。

关 键 词:电除尘  结焦原因  预防措施

On Reasons and Preventive Measures of Internal Coking of Electrostatic Precipitator
HU Xin-li.On Reasons and Preventive Measures of Internal Coking of Electrostatic Precipitator[J].Value Engineering,2014(10):49-50.
Authors:HU Xin-li
Institution:HU Xin-li ( Datang Huxian Thermal Power Plant, Huxian 710302, China )
Abstract:This article describes the internal coking situation of the Datang International Power Co-Ltd's 2×600MW unitsj electrostatic precipitator (ESP) and analyzes the reasons on internal coking of the third, fourth and fifth electric field. At the same time, in this paper, some technical measures are proposed what make to prevent coking within the ESP. In addition, the paper solves the problem of ash transporting pipeline jamming and serious coking within ESP which can cause the blowing-out.
Keywords:electrostatic precipitator (ESP)  the reason on coking  preventive measure