钼蓝光度法测定钼铁中磷量的不确定度评定
引用本文:王慧,许玉宇,王国新,胡清,朱玉燕.钼蓝光度法测定钼铁中磷量的不确定度评定[J].检验检疫科学,2010,20(2):40-43.
作者姓名:王慧  许玉宇  王国新  胡清  朱玉燕
作者单位:常熟出入境检验检疫局,江苏常熟,215500
摘    要:按照国家标准GB/T5059.6-2007中的方法Ⅱ进行钼铁中磷含量的测定,对测定过程中产生不确定度的原因进行分析,并对测量结果的不确定度进行评定。该方法测定磷量的扩展不确定度U=0.002%,置信区间为95%。

关 键 词:钼蓝光度法    测量不确定度

Evaluation of Measurement Uncertainty for Determination of Phosphorus Content in Ferromolybdenum by Molybdenum Blue Spectrophotometric Method
Wang Hui,Xu Yuyu,Wang Guoxin,Hu Qing,Zhu Yuyan.Evaluation of Measurement Uncertainty for Determination of Phosphorus Content in Ferromolybdenum by Molybdenum Blue Spectrophotometric Method[J].Inspection and Quarantine Science,2010,20(2):40-43.
Authors:Wang Hui  Xu Yuyu  Wang Guoxin  Hu Qing  Zhu Yuyan
Institution:Wang Hui,Xu Yuyu,Wang Guoxin,Hu Qing,Zhu Yuyan(Changshu Entry-Exit Inspection , Quarantine Bureau,Changshu,Jiangsu,215104)
Abstract:Phosphorus content in ferromolybdenum was determined according to the second method in GB/T 5059.6-2007.The sources of the uncertainty in measurement were analyzed and discussed,moreover,the uncertainty in measurement was calculated and evaluated.The expanded uncertainty of this method was 0.002 % with under confidence probability of 95%.
Keywords:Molybdenum blue spectrophotometric method  Phosphorus  Measurement uncertainty  