Development,construction, and use of pneumometric tubes for measurement of steam flow in the steam lines of PVG-1000 at NPP
Authors:Yu S Gorbunov  A G Ageev  R V Vasil’eva  B M Korol’kov
Institution:(1) FGUP “élektrogorsk Scientific-Research Center for NPP Safety,”, élektrogorsk, Moscow Oblast’, Russia
Abstract:A system for the direct measurement of steam flow in steam lines after a steam generator, which utilizes a special design of pneumometric tubes and a computing unit that accounts for variation in steam pressure, has been developed to improve the quality of water-level regulation in the steam generators of VVéR-1000 power-generating units in the stationary and transitional modes. The advantage of the pneumometric tubes consists in their structural simplicity, high erosion resistance, and absence of irrevocable losses during measurement of steam flow. A similar measurement system is used at foreign NPP. The measurement system in question has been placed in experimental service at the No. 3 unit of the Balakovo NPP, and has demonstrated its worthiness. This measurement system can also be used to determine steam flow in the steam lines of NPP units with VVéR-1000 and VVéR-440 reactors, and PBMK-1000 power-generating units. __________ Translated from élektricheskie Stantsii, No. 3, March 2007, pp. 23–26.
Keywords:NPP  steam generator  water level  automated level-regulation system  indirect measurement  inertia  signal  steam-flow rate  pneumometric tube  computing unit  dynamic operating mode of power-generating unit