首页 | 本学科首页   官方微博 | 高级检索  
     检索      

Fenton试剂处理氯氰菊酯废水的试验研究
引用本文:张洪波.Fenton试剂处理氯氰菊酯废水的试验研究[J].科技与企业,2013(22):371-372.
作者姓名:张洪波
作者单位:连云港市环境监测中心站,江苏连云港222001
摘    要:对Fenton试剂处理氮氰菊酯废水的效果进行了研究。考察了pH值、投加量、反应时间、反应温度等因素对处理效果的影响。通过试验确定的最佳处理条件:pH值为5,芬顿试剂投加量为50mg/L,温度为20℃,反应时间为60min,此时COD。去除率在42%。

关 键 词:Fenton试剂  废水  氮氰菊酯

Experimental Study of Fenton's Reagent Treated cypermethrin Wastewater
Zhang Hong-bo.Experimental Study of Fenton's Reagent Treated cypermethrin Wastewater[J].Science-Technology Enterprise,2013(22):371-372.
Authors:Zhang Hong-bo
Institution:Zhang Hong-bo (Lianyungang. City Environmental Monitoring Center Station, Lianyungang 222001, Jiangsu, China)
Abstract:It studied on the treatment effect of using Fenton's agent processing cypermethrin wastewater under different operating conditions. It mainly investigated some important factors on the treatment effect, such as pH, dosageof Fenton's agent, reaction time and reaction temperature. At last, the best conditions were obtained under the following: the pH was 3, the dosage of Fenton's agent is 50 mg/L , reaction time was 60 min, reaction temperature was 20 oC. The results showed that the removal rate of wastewater CODcr reached 42%.
Keywords:Fenton' s reagent  wastewater  cypermethrin